Gosport Borough Council - Living Gosport Borough Council - link to living Gosport Borough Council - link to your council Gosport Borough Council| Gosport Borough Council - Enjoying Gosport Borough Council - link to enjoying Gosport Borough Council - link to working Gosport Borough Council - Working| Gosport Borough Council - Community Gosport Borough Council - link to community Gosport Borough Council - link to environment Gosport Borough Council - Environment

Gosport Borough Council
Town Hall
High Street
Gosport
Hampshire
PO12 1EB
Tel: (023) 9258 4242
| How to contact us |
| How to get to us |
| Online Map |

  • Gosport Choice
  • Gosport Youth Council
  • Portsmouth Fairtrade Forum
  • Dixerit - Read this page
  • Starthere website
  • Direct Government Website
  • Hampshire County Council
  • Gosport Borough Council - I am moving
  • NHS Direct
  • Investors in People
.

Pressure Systems and Gas Cyclinders

 
 
 
 
 
 
 
 
 
 
 
 
 
 
INTRODUCTION
 
If pressure systems fail, they can seriously injure or kill people. Every year there are about 150 dangerous occurrences (reported to the Health and Safety Executive), involving unintentional releases of gas or fluid from pressure systems. Around six of these result in fatal or serious injury. The Pressure Systems Safety Regulations 2000 came into force in February 2000; they updated and consolidated previous legislation. They deal with the risks created by a release of stored energy should the system fail, and detail the measures that should be taken to prevent failures and reduce risks.
 
The Pressure Systems Safety Regulations apply to all plant/systems which contain a relevant fluid. A relevant fluid is defined as steam or gas under pressure and liquids under pressure which become gases upon release to the atmosphere, at a pressure greater than 0.5 bar (about 7psi) above atmospheric (except for steam). Certain small vessels, where the combination of the internal volume and pressure of the vessel is less than 250 bar litres are exempt from some parts of the Regulations. Where the relevant fluid is steam, all the regulations apply, irrespective of the vessel pressure.
 
LEGAL REQUIREMENTS
 
The Regulations require users to:-
· establish the safe operating limits of the plant
· have a suitable written scheme drawn up or certified by a competent person for the examination at appropriate intervals of
- most pressure vessels
- all safety devices
- any pipe work which is potentially dangerous [NB Pipe work produces the majority of known release incidents]
· arrange to have examinations carried out by a competent person at the intervals set down in the scheme.
· provide adequate operating instructions (including emergency instructions) to any person operating it (e.g. operating manual supplemented by on-the-job training and supervision for new staff)
· ensure the pressure system is maintained in good repair
· keep adequate records of the most recent examination and any manufacturer's records supplied with the new plant. The Regulations distinguish between those systems which are essentially fixed in a permanent location (installed) and those which are normally and frequently moved from place to place (mobile). For installed systems the user is responsible for ensuring that the above items are carried out. In the case of mobile systems the owner is responsible.
SAFE OPERATING LIMITS
 
Reg. 7 prohibits the use of systems unless the user of an installed system and the owner of a mobile system has determined safe operating limits (SOL's). SOL's for small simple systems are basically the upper limits of pressure and temperature for which the plant was designed to be operated safely. The competent person will review and reassess the SOL's when the plant is examined. They should always be reassessed when the plant or part of it is repaired or modified.
 
WRITTEN SCHEMES OF EXAMINATION
· The typical contents of a written scheme of examination would include:-
· identification number of the item of plant or equipment
· those parts to be examined
· nature of the examination required
· any necessary preparatory work to enable the item to be examined safely
· specify what examination is necessary before the system is first used, where appropriate
· the maximum interval between one examination and the next
· the critical parts of the system which if modified or repaired should be examined by a competent person before the system is used again.
· name of the competent person certifying the written scheme of examination
· the date of certification
Examples of pressurised systems likely to require a written scheme of examination are:-
· a compressed air receiver and associated pipework where the product of the pressure times the internal capacity of the receiver is greater than 250 bar litres
· a pressure cooker and autoclave
· a steam boiler, associated pipework and protective devices, and steam heating devices
· a portable hot water/steam cleaning unit
· a fixed LPG storage system supplying fuel for heating in a workplace
· a vapour compression refrigeration system where the installed power exceeds 25kW
Examples of pressurised systems unlikely to require a written scheme of examination are:-
· an office hot water urn
· a machine tool hydraulic system
· a hand held tool
· portable oxy-fuel gas welding sets
· a compressed air receiver and associated pipework where the product of the pressure times the internal capacity of the receiver is less than 250 bar litres
· a portable LPG cylinder
· a tyre used on a vehicle
· any pipeline and its protective devices in which the pressure does not exceed 2 bar above atmospheric pressure
 
 
 
 
 
 
 
 
 
 
 
COMPETENT PERSON
 
The references to a "competent person" in the Regulations should be taken to mean an organisation employing individuals who are competent (by knowledge, experience and independence) to carry out the relevant duties. Accreditation to BS EN 45004 : 1995 [General criteria for operation of the various types of bodies performing inspection] is an indication of the competence of an inspection department, organisation or self-employed person. This is recommended for bodies acting as competent persons engaged to draw up or certify a written scheme of examination or conduct examinations for major systems. The first examination under the written scheme for new plant will generally need to be carried out before the complete system is taken into use for the first time.
 
TRANSPORTABLE GAS CONTAINERS (GAS CYLINDERS)
 
The main controls under the Regulations concern the manufacture and importation of new cylinders and the over filling of all existing gas cylinders. Cylinders must therefore be made to approved designs. There are also duties on anyone who modifies or repairs cylinders.
 
SAFETY WHEN USING GAS CYLINDERS
Suppliers of commonly used industrial gases produce a range of safety information about their cylinders, which may contain propane, oxygen, acetylene, carbon dioxide for example. In general terms they cover:-
· Information about the cylinders (design, construction, identification)
· Information about the gases
· Carriage, handling/lifting of cylinders
· Storage (ideally in the open with protection from the weather; upright; protective clothing; segregation as appropriate)
· Care of cylinders (e.g. avoidance of heat, oil or grease; cleanliness)
· Making safe connections (e.g. compatibility of threads; appropriate regulators; flashback arrestors where appropriate)
· Choosing safe equipment (gauges; hoses; end connections; flashback arrestors; use of correct personal protective equipment)
· Avoiding contamination from backflow
· Keeping equipment safe (regular checks etc)
· Emergency procedures
· Environmental safety precautions
CHECKLIST - PRESSURE SYSTEMS & GAS CYLINDERS
Pressure Systems
1 (a) Do you have pressure systems which contain a "relevant fluid" where the pressure times volume of the largest pressure vessel is less than 250 bar litres?
1 (b) If 'yes', have you established safe operating limits and do you maintain the system properly?
2. Do you have pressure systems which contain a 'relevant fluid' where the pressure x volume of the largest pressure vessel is greater than 250 bar litres or a system containing steam?
If 'yes':-
3. Have you established the safe operating limits?
4. Has a written scheme of examination been drawn up or certified by a competent person?
5. Have examinations been carried out by an competent person in accordance with the written scheme?
6. Do you provide adequate operating instructions?
7. Do you keep the system properly maintained?
8. Do you keep adequate records of examination etc?
Gas cylinders
1. Do you obtain cylinders from a reputable supplier?
2. Do you ensure that cylinders are stored, handled and used in accordance with safe practice?
3. Do you have adequate information and provide adequate training and instruction to employees regarding safety with gas cylinders?
 
REFERENCES/FURTHER DETAILS
2. HELA Circular 66/6 - Pressure Systems etc Regs 1989
3. Booklet HS (G) 39 - Compressed Air Safety
4. HSE Safety Policy Sheet No. 1 - The Pressure Systems and Transportable Gas Containers Regs 1989
5. L122 Safety of Pressure Systems. Pressure Systems Safety
Regulations 2000. Approved Code of Practice.
For further information please call (023) 9254 5505, 5506 or 5507 during office hours or call at the Town Hall, High Street, Gosport, Hampshire PO12 1EB.
Alternatively e-mail ehs@gosport.gov.uk any time